HUADONG builds marine diesel generator sets from 8 kW to 250 kW for shipboard auxiliary power. Each set pairs a HUADONG 2110 / 490 / 4100 / 4105 / 6105 / 6126 series marine engine with a brushless Landian, Kangfu or Haihang alternator, in open type or silent type, and every rating can be supplied with a CCS classification certificate. Voltage, frequency and phase are built to your order – 400/220 V, 50/60 Hz, three-phase four-wire is the standard configuration. Minimum order is 1 unit.
At a Glance
| Power Range | 8 – 250 kW normal · 9.6 – 275 kW reserve |
| Voltage | 400/220 V, three-phase four-wire – other voltages to order |
| Frequency | 50 Hz and 60 Hz |
| Alternator | Brushless with AVR, from Landian (Lanzhou Electric), Kangfu or Haihang of Wenling |
| Engine | HUADONG 2110 / 490 / 4100 / 4105 / 6105 / 6126 series, Ricardo technology |
| Enclosure | Open type and silent (soundproof) type |
| Certification | CCS classification certificate available · ISO 9001, CE |
| Minimum Order | 1 unit · OEM branding and custom voltage / frequency supported |
Why Choose HUADONG Marine Generator Sets
Sea-Ready, Not a Land Set Repainted
Marine engines are matched with sea water / fresh water heat exchanger cooling, and the set is built on a rigid base frame with marine instrumentation. Generators can be supplied with CCS classification certificate for vessel registration and classification society survey, which is what most fishing and cargo operators need before installation.
Branded Alternator, Built to Your Own Specification
Every set is coupled to a brushless alternator with automatic voltage regulator from Landian (Lanzhou Electric), Kangfu or Haihang of Wenling, and you choose which of the three goes on your order. 400/220 V, 50 Hz or 60 Hz three-phase four-wire is standard, and we build single phase, 380 V, 415 V, 440 V, 220 V and other voltages and frequencies to your order – so the set matches the equipment already on board instead of the other way round.
Compact, Easy to Install, Cheap to Run
The compact structure keeps the set within the footprint of a small engine room and makes lifting and transport simple. Direct-injection Ricardo-technology engines hold fuel consumption down under continuous load, and maintenance is straightforward with widely available spare parts.
Key Features
- ✓18 standard ratings from 8 kW to 250 kW, in 50 Hz and 60 Hz
- ✓HUADONG 2110 / 490 / 4100 / 4105 / 6105 / 6126 series marine engines
- ✓Ricardo-technology engines across the 4100 / 4105 / 6105 range
- ✓Brushless alternator with AVR from Landian (Lanzhou Electric), Kangfu or Haihang of Wenling – your choice of brand confirmed on the order acknowledgement
- ✓400/220 V three-phase four-wire standard; custom voltage, frequency and phase on request
- ✓Open type and silent (soundproof) type, both available on every rating
- ✓Forced water cooling with sea water / fresh water heat exchanger; keel cooling is not offered
- ✓Electric starting, engine safety protections on low oil pressure and high water temperature
- ✓Single-set operation – parallel running with a second set is not offered
- ✓CCS classification certificate can be supplied for vessel survey and registration
- ✓Compact structure, easy to lift and transport into small engine rooms
- ✓Low fuel consumption and long service life, with low maintenance cost
- ✓Minimum order quantity 1 unit, OEM branding, colour and nameplate customisation
Type Configuration – 8 kW to 250 kW
| No | Genset Model | Normal Power (kW) | Reserve Power (kW) | Rated Current (A) | Voltage (V) | Frequency (Hz) | Diesel Engine Model | Open Type | Silent Type |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CCFJ08J | 8 | 9.6 | 14.4 | 400/220 | 50/60 | 2110CD | ✓ | ✓ |
| 2 | CCFJ10J | 10 | 11 | 18 | 400/220 | 50/60 | 2110CD | ✓ | ✓ |
| 3 | CCFJ12J | 12 | 13.2 | 21.6 | 400/220 | 50/60 | 2110CD | ✓ | ✓ |
| 4 | CCFJ15J | 15 | 16.5 | 27 | 400/220 | 50/60 | 490CD | ✓ | ✓ |
| 5 | CCFJ20J | 20 | 22 | 36 | 400/220 | 50/60 | 490ZCD | ✓ | ✓ |
| 6 | CCFJ24J | 24 | 26.4 | 43.2 | 400/220 | 50/60 | ZH4100CD | ✓ | ✓ |
| 7 | CCFJ30J | 30 | 33 | 54 | 400/220 | 50/60 | ZH4100ZCD | ✓ | ✓ |
| 8 | CCFJ40J | 40 | 44 | 72 | 400/220 | 50/60 | R4105ZCD | ✓ | ✓ |
| 9 | CCFJ50J | 50 | 55 | 90 | 400/220 | 50/60 | R4105IZCD | ✓ | ✓ |
| 10 | CCFJ64J | 64 | 70.4 | 115.2 | 400/220 | 50/60 | R4105IZLD | ✓ | ✓ |
| 11 | CCFJ75J | 75 | 82.5 | 135 | 400/220 | 50/60 | R6105ZCD | ✓ | ✓ |
| 12 | CCFJ80J | 80 | 88 | 144 | 400/220 | 50/60 | R6105AZLCD | ✓ | ✓ |
| 13 | CCFJ90J | 90 | 99 | 162 | 400/220 | 50/60 | R6105AZLCD | ✓ | ✓ |
| 14 | CCFJ100J | 100 | 110 | 180 | 400/220 | 50/60 | R6105IZLD | ✓ | ✓ |
| 15 | CCFJ120J | 120 | 132 | 216 | 400/220 | 50/60 | R6108IZLCD | ✓ | ✓ |
| 16 | CCFJ150J | 150 | 165 | 270 | 400/220 | 50/60 | HD6126ZLCD | ✓ | ✓ |
| 17 | CCFJ200J | 200 | 220 | 360 | 400/220 | 50/60 | HD6126ZLCD | ✓ | ✓ |
| 18 | CCFJ250J | 250 | 275 | 450 | 400/220 | 50/60 | HD6126IZLCD | ✓ | ✓ |
Normal power is the continuous rating; reserve power is the standby rating available for limited hours. All ratings are three-phase, four-wire, 400/220 V, 50/60 Hz with a power factor of 0.8. Open type and silent type can be supplied on every rating.
Open Type Dimensions and Weight
| Genset Model | Normal Power | Open Type Size L x W x H | Weight |
|---|---|---|---|
| CCFJ10J | 10 kW | 1300 x 670 x 1030 mm | 630 kg |
| CCFJ12J | 12 kW | 1300 x 670 x 1030 mm | 680 kg |
| CCFJ15J | 15 kW | 1680 x 630 x 1000 mm | 750 kg |
| CCFJ20J | 20 kW | 1680 x 630 x 1000 mm | 780 kg |
| CCFJ24J | 24 kW | 1680 x 630 x 1000 mm | 800 kg |
| CCFJ30J | 30 kW | 1700 x 800 x 1100 mm | 900 kg |
| CCFJ40J | 40 kW | 1700 x 800 x 1100 mm | 1000 kg |
| CCFJ50J | 50 kW | 1800 x 800 x 1100 mm | 1050 kg |
| CCFJ75J | 75 kW | 2300 x 800 x 1270 mm | 1300 kg |
| CCFJ100J | 100 kW | 2400 x 800 x 1270 mm | 1450 kg |
| CCFJ120J | 120 kW | 2400 x 800 x 1270 mm | 1550 kg |
| CCFJ150J | 150 kW | 2400 x 800 x 1270 mm | 1600 kg |
| CCFJ200J | 200 kW | 2700 x 1100 x 1800 mm | 1950 kg |
| CCFJ250J | 250 kW | 2700 x 1100 x 1800 mm | 2100 kg |
Figures published for these ratings in the HUADONG generator set catalogue. Silent type dimensions and weights differ – ask us for the drawing of the rating you need.
Typical Applications
HUADONG marine generator sets are installed as auxiliary generating sets on:
- Fishing vessels – trawlers, purse seiners and gillnetters running refrigeration, winches and deck lighting at sea
- Ro-ro and passenger vessels, ferries and water buses
- General cargo ships, bulk carriers and coasters
- Tugs, pilot boats, patrol boats and workboats
- Dredgers, sand carriers and barges
- Offshore support vessels, aquaculture and floating platforms
Frequently Asked Questions
What is the minimum order quantity?
One unit. We accept trial orders and single-set orders for new vessel projects, and OEM branding is available from the first set.
Can you build a set for our voltage and frequency?
Yes. 400/220 V, 50/60 Hz, three-phase four-wire is the standard build, and we also produce single phase, 380 V, 415 V, 440 V and other combinations to order.
Do your marine generator sets come with a CCS certificate?
Yes. Every rating in the range can be supplied with a CCS classification certificate for vessel registration and classification society survey.
Which alternator is fitted?
A brushless alternator with automatic voltage regulator from Landian (Lanzhou Electric), Kangfu or Haihang of Wenling. We normally build with one of these three, you pick the one you prefer, and the brand and model are confirmed on the order acknowledgement so it matches your specification.
Can these sets run in parallel?
No. These sets are built for single-set operation and are not equipped for parallel running or load sharing with a second set.
Do you offer keel cooling?
No. Cooling is forced water cooling through a sea water / fresh water heat exchanger, which suits the majority of fishing boats, tugs, barges and cargo vessels. Keel cooling is not offered on this range.
Open type or silent type - which should we choose?
Open type suits a dedicated engine room with good ventilation. Silent type adds a soundproof canopy and is used where the set is close to accommodation or working areas. Both are available on all ratings from 8 kW to 250 kW.
Get a Quote
Tell us your vessel type, the power you need and the voltage and frequency used on board. We will confirm the matching CCFJ rating, the engine and alternator selection, the CCS certificate and the delivery schedule. Datasheets, drawings and certification copies are available on request. MOQ is 1 unit and OEM customisation is supported.